An experimental VLE data set gives a small integrated area. Is that enough to trust it? Establish a synthetic control, construct a counterexample, then defend a limited conclusion about measured data.
Complete Steps 1–5. Submit numerical comparisons, an assumption audit, and a decision that distinguishes consistency evidence from measurement accuracy.
No experimental file is needed for this lab. Use the supplied cases to learn what each consistency test can detect. Start with case A, compare B and C, then inspect the published measurements in Step 4.
Component 1 is 2-propanol (isopropanol); component 2 is water. x1 and y1 are the mole fractions of 2-propanol in the liquid and vapor, respectively. T is in K and P is in kPa.
Cases A–C · Generated practice data
The generator uses the article's NRTL parameters and NIST Antoine correlations. These are simulated states, not laboratory measurements.
A: fix T = 350 K; calculate P and y1 at 81 liquid compositions.
B: alter the generated activities deliberately, then recalculate P and y1.
C: fix P = 60 kPa; solve T and y1 at each liquid composition.
The generator supplies endpoint activity limits and HE. Changing 41 / 81 / 161 points changes the sampling grid.
Case D and the 80 kPa option · Measured data
Barbieri, De Guido and Moioli (2024), Tables 4–5, report 20 measured T–P–x–y states at each pressure.
60 kPa: 18 usable activity pairs; two pure endpoints cannot determine the absent component's activity.
80 kPa: 17 usable pairs; two pure endpoints and one state outside the common Antoine range are excluded from activity inference.
All original rows remain visible. Psat and γ are calculated, not measured here. Independent HE is unavailable.
What your controls change: endpoint options add assumed curves; Step 4 measurement shifts create separate sensitivity scenarios. The original measured rows remain unchanged. After learning the tests here, use Lab 08 to enter your own VLE measurements.
Where do the model and property values come from?
The generating NRTL parameters are from Table 7 of the same article. Pure-component Psat values use the supplied 2-propanol and water Antoine records from NIST, within their common range of 334–362.41 K. Synthetic HE is derived from the generating NRTL model; it is not independent calorimetry.
On a narrow screen, scroll the drawing horizontally. The three explanations below remain readable without scrolling.
1. Do areas cancel?
A small net area can hide errors of opposite sign.
2. Does the local identity hold?
Derivatives can reveal a defect, but amplify noise and spacing effects.
3. Can this model reproduce the data?
A fit tests a chosen model, property assumptions and numerical procedure together.
Teal is the reference. Amber highlights a local departure or model prediction; sand marks integrated area. No single criterion certifies the accuracy of every measurement.
Loading the source measurements and calculation methods…